In medicine, AI agents are moving from generating text to executing actions, making uncertainty from upstream decoders a control problem. We studied this at the brain-computer interface using 1,065 episodes from 47 people with amyotrophic lateral sclerosis and five language models. Prompting agents with reconstructed decoder confidence never reduced unfaithful execution below a deterministic gate at matched coverage; two models were significantly worse.
AI agents at the brain-computer interface: separating inference from control
calendar_today
September 17, 2026
person
Gorenshtein, A., Omar, M., Jia, E. L., Adiniaev, Y., Daniel, O., Kruskal, J., Ahmed, M., Brook, O. R., Klang, E., Barash, Y.